Medicare is Supplier of Medical Equipment and Hospital Furniture. Please call us on 011 392 1120 / 021 948 9987 / 012 803 1652 or send an email to info@medicare.co.za for enquiries.

AED Cusp2

Ambient noise detection [Auto volume adjusting]
Easy-to-use & manage Electrode (Displaying Life expectancy of Electrode)
Graphic LCD status Indicator (Device, Pads & Battery)
Selectable Voice guide for both Lay Rescuer and Healthcare provider
ECG monitoring or multi printing via Bluetooth communication

• Product Exterior
Dimensions: 260 x 256 x 70 mm (Width x Length x Height)
LCD: 5inch wide, 480×272 16bit
Weight 2.4㎏ (Including the battery pack and pads)

• Defibrillator
Operation Type: Dual Mode (semi-automated, manual) External Defibrillator
Output Type: e-cube biphasic (Truncated exponential type) output Energy
AED Mode
• 150J±4J, 200J±6J at 50Ω load for adults
• 50J±2J at 50Ω load for children
Manual Mode
• 2J±1J, 3J±1J, 5J±1J, 7J±1J, 10J±1J, 20J±2J, 30J±2J, 50J±2J, 70J±2J, 100J±4J, 150J±4J, 200J±6J at 50Ω load

• Self Test
Auto Power Self-Test / Real-time Self-Test
Daily / Weekly / Monthly Self-Test
Manual Battery Pack Self-Test (performed when the user inserts the battery pack)

• ECG Analysis System
Analyzes whether the rhythms of the patient’s impedance and ECG require a defibrillation
Measured Impedance Range 25Ω ~ 175Ω

• Battery

Standard
+ Type : DC 12 Volt 2.8 Ah, Lithium manganese dioxide
+ Capacity : Minimum 100shocks (150J )

High Capacity
+ Type : DC 12Volt 4.2Ah, Lithium manganese dioxide
+ Capacity : Minimum 200shocks (150J )

Lifespan 5 years (High capacity battery)
(With the condition of the temperature of operation/
standby, standby mode after the first initial check)

• Electrode
Adult
Electrode Area: 110 cm2
Cable Length: Total 120cm (Internal: 95cm, External: 25cm)
Pediatric
Electrode Area: 50 cm2
Cable Length: Total 120cm (Internal: 80cm, External: 40cm)

• Data Storage and Transfer
Data Storage: Saves 3 events on the internal memory (up to 17 hours per event)
SD Card: Stores the ECG and event data from the device’s internal memory through the PC software (CU-Expert).
Bluetooth: Uses Bluetooth to communicate with the Printer or the CUEM1
(ECG transmission device)

SKU: MHE-AEDC2 Categories: , , Tags: ,

Description

Ambient noise detection [Auto volume adjusting]
Easy-to-use & manage Electrode (Displaying Life expectancy of Electrode)
Graphic LCD status Indicator (Device, Pads & Battery)
Selectable Voice guide for both Lay Rescuer and Healthcare provider
ECG monitoring or multi printing via Bluetooth communication

• Product Exterior
Dimensions: 260 x 256 x 70 mm (Width x Length x Height)
LCD: 5inch wide, 480×272 16bit
Weight 2.4㎏ (Including the battery pack and pads)

• Defibrillator
Operation Type: Dual Mode (semi-automated, manual) External Defibrillator
Output Type: e-cube biphasic (Truncated exponential type) output Energy
AED Mode
• 150J±4J, 200J±6J at 50Ω load for adults
• 50J±2J at 50Ω load for children
Manual Mode
• 2J±1J, 3J±1J, 5J±1J, 7J±1J, 10J±1J, 20J±2J, 30J±2J, 50J±2J, 70J±2J, 100J±4J, 150J±4J, 200J±6J at 50Ω load

• Self Test
Auto Power Self-Test / Real-time Self-Test
Daily / Weekly / Monthly Self-Test
Manual Battery Pack Self-Test (performed when the user inserts the battery pack)

• ECG Analysis System
Analyzes whether the rhythms of the patient’s impedance and ECG require a defibrillation
Measured Impedance Range 25Ω ~ 175Ω

• Battery

Standard
+ Type : DC 12 Volt 2.8 Ah, Lithium manganese dioxide
+ Capacity : Minimum 100shocks (150J )

High Capacity
+ Type : DC 12Volt 4.2Ah, Lithium manganese dioxide
+ Capacity : Minimum 200shocks (150J )

Lifespan 5 years (High capacity battery)
(With the condition of the temperature of operation/
standby, standby mode after the first initial check)

• Electrode
Adult
Electrode Area: 110 cm2
Cable Length: Total 120cm (Internal: 95cm, External: 25cm)
Pediatric
Electrode Area: 50 cm2
Cable Length: Total 120cm (Internal: 80cm, External: 40cm)

• Data Storage and Transfer
Data Storage: Saves 3 events on the internal memory (up to 17 hours per event)
SD Card: Stores the ECG and event data from the device’s internal memory through the PC software (CU-Expert).
Bluetooth: Uses Bluetooth to communicate with the Printer or the CUEM1
(ECG transmission device)