Creative Multi-parameter ICU Patient Monitor UP-7000 with 12″TFT Display

NIBP

Technique: Oscillometric
Typical measuring time: <30 seconds (typical adult cuff)
Initial cuff inflation pressure: Adult <175mmHg
Pediatric <135mmHg
Neonate <65mmHg
Overpressure protection limit: Adult 300mmHg
Pediatric 240mmHg
Neonate 150mmHg
Measuring range
Systolic pressure: Adult 40mmHg~275mmHg
Pediatric 40mmHg~200mmHg
Neonate 40mmHg~135mmHg
Diastolic pressure: Adult 10mmHg~210mmHg
Pediatric 10mmHg~150mmHg
Neonate 10mmHg~95mmHg
Mean arterial pressure: Adult 20mmHg~230mmHg
Pediatric 20mmHg~165mmHg
Neonate 20mmHg~110mmHg
Measurement accuracy: Maximum mean difference: ±5 mmHg
Maximum standard deviation: 8 mmHg
Measurement mode: Manual, Auto, STAT
Automatic measuring intervals: 1~480min

TEMP

Measuring range: 21.0°C~50.0°C
Measuring accuracy: ±0.2°C for range from 25.0°C~45.0°C

SpO2

Transducer: Dual-wave length LED
SpO2 measuring range: 0%~100%
SpO2 measuring accuracy: 2% for range from 70% to 100%
Low perfusion performance: As low as 0.4%
PR measuring range: 0bpm~250bpm
PR measuring accuracy: ±2bpm or ±2%, whichever is greater

ECG

Input dynamic range: ±0.5mVp~±5mVp
HR measuring range: 15bpm~350bpm
HR measuring accuracy: ±1% or ±2bpm, whichever is greater
HR alarm delay time: ≤10s
Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
Sweeping speed: 6.25mm/s,12.5mm/s, 25mm/s, 50mm/s
ECG noise level: ≤30μVp-p
ECG input loop current: ≤0.1μA
Differential input impedance: ≥10Mohm
Common-mode rejection ratio: ≥105dB (Monitoring mode)
(CMRR) ≥89dB (Diagnostic mode)
Time constant: ≥0.3s (Monitoring mode)
≥3.2s (Diagnostic mode)

RESP

RR measuring range: 0rpm~120rpm
RR measuring accuracy: ±5% or ±2rpm, whichever is greater

Others

Power supply: 100~240Vac, 50/60Hz
Display: 12.1 inch TFT display

Built-in battery: 4400mAh Lithium battery
Alarming mode: Audible-visual alarm
Networking port: Ethernet port

Standard Configuration

ECG, RESP, SpO2, NIBP, TEMP, PR

Option

2-IBP, EtCO , Nellcor SpO , SunTech NIBP, Cardiac Output, Built-in printer,
Cerebral State Monitoring, Central monitoring system, Touch screen

Description

Creative Multi-parameter Patient Monitor UP-7000 with 12″TFT Display for Critical Care (ICU) Use in Hospital.

Multi-parameter Patient Monitor NIBP

Technique: Oscillometric
Typical measuring time: <30 seconds (typical adult cuff)
Initial cuff inflation pressure: Adult <175mmHg
Pediatric <135mmHg
Neonate <65mmHg
Overpressure protection limit: Adult 300mmHg
Pediatric 240mmHg
Neonate 150mmHg
Measuring range
Systolic pressure: Adult 40mmHg~275mmHg
Pediatric 40mmHg~200mmHg
Neonate 40mmHg~135mmHg
Diastolic pressure: Adult 10mmHg~210mmHg
Pediatric 10mmHg~150mmHg
Neonate 10mmHg~95mmHg
Mean arterial pressure: Adult 20mmHg~230mmHg
Pediatric 20mmHg~165mmHg
Neonate 20mmHg~110mmHg
Measurement accuracy: Maximum mean difference: ±5 mmHg
Maximum standard deviation: 8 mmHg
Measurement mode: Manual, Auto, STAT
Automatic measuring intervals: 1~480min

TEMP

Measuring range: 21.0°C~50.0°C
Measuring accuracy: ±0.2°C for range from 25.0°C~45.0°C

SpO2

Transducer: Dual-wavelength LED
SpO2 measuring range: 0%~100%
SpO2 measuring accuracy: 2% for range from 70% to 100%
Low perfusion performance: As low as 0.4%
PR measuring range: 0bpm~250bpm
PR measuring accuracy: ±2bpm or ±2%, whichever is greater

ECG

Input dynamic range: ±0.5mVp~±5mVp
HR measuring range: 15bpm~350bpm
HR measuring accuracy: ±1% or ±2bpm, whichever is greater
HR alarm delay time: ≤10s
Sensitivity selection: ×1/4, ×1/2, ×1, ×2, ×4 and Auto
Sweeping speed: 6.25mm/s,12.5mm/s, 25mm/s, 50mm/s
ECG noise level: ≤30μVp-p
ECG input loop current: ≤0.1μA
Differential input impedance: ≥10Mohm
Common-mode rejection ratio: ≥105dB (Monitoring mode)
(CMRR) ≥89dB (Diagnostic mode)
The time constant: ≥0.3s (Monitoring mode)
≥3.2s (Diagnostic mode)